I、Product Description
According to GB / t13531, ASTM d287 and other specifications. The buoyancy method of Archimedes principle is applied to quickly read the API values of relative density,concentration and specific gravity of oil products.II.Performance Characteristics.
II、API coefficient Description
It refers to the coefficient of relative density conversion API. The relative density of liquid and API cannot show an absolute linear relationship, but a certain curve relationship. The equipment adopts a unique 4-point curve algorithm to convert the relative density of various liquids to API. The 4-point curve algorithm has higher accuracy than the 2-point linear algorithm. Under different temperatures, the relative density conversion API coefficients of the same liquid are different. The equipment has built-in multiple groups of oil products (petroleum, crude oil, glycerol, lubricating oil, etc.) Concentration conversion coefficient at no temperature.
III、Digital display direct reading
relative density (specific gravity), specific gravity API, concentration... And other parameters.
IV、Applicable liquids
petroleum, crude oil, etc.
V、Product features
Touch operation, one key selection of petroleum API value, without cumbersome setting steps, the operation is simple and easy to understand;
The unique multi-point curve concentration measurement algorithm is used to test the API of various oil products (such as crude oil, petroleum, lubricating oil, etc.), and the API accuracy can reach ± 0.1%. Compared with the common two-point linear API measurement algorithm in the market, the multi-point curve API algorithm has higher accuracy;
The built-in temperature setting compensation function can quickly set the temperature value of the crude oil to be measured. The thermostatic equipment mam-hw-1008 can also be selected to measure the density / concentration / Baume value of the crude oil at a specific temperature (such as 25 ℃);
The instrument is operated by microcomputer touch screen, and the parameter settings in Chinese and English are clear at a glance; And each operation step can be reversed (for example, if you find a problem in any operation step, you can return to the step and operate again without starting from scratch);
Equipped with anti-corrosion and high temperature accessories, it is suitable for most liquid detection and 0 consumables in the use process.
VI、Technical parameter
Model | HZSD-29B |
Max load | 150g |
AIP scope | 0.01~100.00° |
API accuracy | 0.01°API |
Temperature resistance range | -20~270℃ |
measuring principle | Substitution method of Archimedes principle |
Temperature compensation range | 0-110℃ |
Measurement time | 5 seconds |
The results show that | Density, API degree |
Density / concentration resolution range | 0.001~99.999g/cm ³ / 0.01%~100% |
supply voltage | AC100V~240V 50HZ/60HZ |