在线客服系统
Products
HZSF-641 SF6 Comprehensive Analyzer SF6 Switch Gas Density Relay Calibrator Tester SF6 Gas Leakage Detector
HZSF-641 SF6 Comprehensive Analyzer SF6 Switch Gas Density Relay Calibrator Tester SF6 Gas Leakage Detector
Contact us
HZSF-641 SF6 Comprehensive Analyzer SF6 Switch Gas Density Relay Calibrator Tester SF6 Gas Leakage Detector
HZSF-641 SF6 Comprehensive Analyzer SF6 Switch Gas Density Relay Calibrator Tester SF6 Gas Leakage Detector
HZSF-641 SF6 Comprehensive Analyzer SF6 Switch Gas Density Relay Calibrator Tester SF6 Gas Leakage Detector
HZSF-641 SF6 Comprehensive Analyzer SF6 Switch Gas Density Relay Calibrator Tester SF6 Gas Leakage Detector

1An overview of the

       SF6 Gas Analyzer adopts imported sensors, set SO2, H2S, moisture content and SF6 purity measurement in one, the original multiple instruments to achieve the function of a centralized instrument, greatly saving the gas in the equipment. The instrument has the characteristics of high precision and stable performance.

       The instrument adopts color LCD touch screen, Windows operating interface, real-time display of various parameters, fully intelligent operation, massive information storage, built-in rechargeable battery, AC and DC dual use.

2The main features

Ø Measures humidity (dew point), purity, decomposition (SO2, H2S) into a single device.

Ø Fully imported precision sensor, dew point measurement automatic zero calibration, anti-oil pollution, anti-drift.

Ø Electronic flow display.

Ø Instrument self-diagnosis function, intelligent electric quantity display.

Ø Supports data communication.

Ø Graphic menu.

Ø Measuring range is wide, precision is high and response is rapid.

Ø Is small, intelligent and fully functional.

Ø Has the function of fast data storage, query and print.

Ø Open calibration: The instrument has a calibration function and only needs to be operated on the instrument to complete the calibration.

Ø AC/DC, with a rechargeable lithium battery built in, capable of operating continuously for several hours.

Ø Probe is not affected in condensation, specific pollution, oil and gas and most chemical environments.

3、Technical indicators

 

SF6 dew point

Measuring range and accuracy

Range: -80℃ ~ +20℃ Accuracy: ±1℃

The resolution of the

Dew point 0.1℃ or 1ppm

The response time

63[90]  +20-20℃ Td 5s[45s]

-20-60℃ Td 10s[240s]

SF6 purity

Measuring range and accuracy

Range: 0 ~ 100% Accuracy: 0.5%

The response time

90%30s

 

SO2

Measuring range

0100ppm

precision

±0.5%

 

H2S

Measuring range

0100ppm

precision

±0.5%

 

 


Related products

HZSF-641 SF6 Gas Analyzer Dew Point Comprehensive SF6 Gas Analyzer sf6 Gas Analyzer Calibration

HZSF-641 SF6 Comprehensive Analyzer SF6 Switch Gas Density Relay Calibrator Tester SF6 Gas Leakage Detector

HZCOP35 SF6 Gas Quantitative Leak Detector SF6 Gas Leak Test Equipment Quantitative Leakage Detector

HZCOP58 SF6 Infrared Quantitative Detector Infrared Principle SF6 Gas Leak Test Equipment Portable high-accuracy Infrared quantitative Gas Leakage Detector

HZSF-641 SF6 Gas Analyzer SF6 Gas Multifunctional Decomposition Moisture Purity Tester Sulfur Hexafluoride Gas Analyzer

+8618330222305 +8618330222305 sales08@bdhuazheng.com 0086-18330222305 Julia Jin-huazheng