Alternate Current VLF Electric Safety Hipot Tester Technicalparameters:ModelPeakvoltageMeasuringrangeWeightPurposeVLF-3030KV0.1Hz,≤1.1µFController:4kgBooster:25kgSize:L*W*H323*174*32310KVandbelowvoltagecable,generator&nb
FunctionsAnd Characters1.Precision inverter three-phase measuring power supply is adopted in the instrument to measure more accurately.2.Adopt three-phase output voltage, three-phase pressure, three-phase simultaneous measurement, improve test speed, and automatically identify transformer wiri
1.transformer oil purification plant FUNCTIONThe main function of DZL Series of signal and double stage high-efficient vacuum oil purifier is to remove free and dissolved water, gases, and mechanical impurities from insulating oils so as to ensure its purity and improve its insulation property. It i
HZGC-1212A chromatograph dedicated transformer oil is the latest of a special component of the determination of dissolved gas dedicated gas chromatograph to electricity insulating oil, the instrument uses advanced triple detection process, with both FID and TCD detector detectors , a single in
Transformer Test Bench Test ability:1)Can meet the capacity of 63000KvA, 110Kv and below the oil-immersed transformer (including S9S11S13 and amorphous alloy transformer);2) It can meet the capacity of 31500KvA, 35Kv and below dry-type transformers;3) Mine explosion-proof transformers th
The vacuum oil purifier is designed according to the different saturated vapor pressures of water and oil. It consists of a coarse filter, an oil feed pump, a heater, a vacuum separation chamber, a vacuum pump, a condenser, a fine filter, an oil drain pump and an electrical cabi
The ultra-low frequency tester is actually an alternative to the power frequency withstand voltage test. We know that when large-scale generators, cables and other samples are subjected to power frequency withstand voltage tests, because their insulating layers exhibit large capacitances, large-capa
In power systems, railway systems and large petrochemical factories and mines, enterprises have a large number of electrical equipment, and most of their internal insulation is oil-filled insulation. The dielectric strength of insulating oil is a routine test that must be measured. In order to meet
DC resistance of transformer is one testing item which must be tested during ex-work test of semi-finished products and final products, installation, acceptance test and preventive test of electric power department, which can effectively find out material selection of transformer coil, welding, loos